Cap
How to Clean an AutoPilot ChlorSync CS Series (CS30, CS40, CS50) Salt Cell
- Turn off the water circulation pump.
- Power off the ChlorSync power center and disconnect the cell from the power center.
- Remove cell from plumbing.
- Remove any loose scale with a garden hose using a high-pressure attachment.
- Place the AutoPilot Acid Wash Kit (part #STK0227) on the end of the cell and hand tighten.
- Fill the capped cell with water two inches from the top of the cell blades.
- Fill the rest of the cell with muriatic acid, being careful not to allow solution to overflow onto the outside of the cell. This allows for an approximate 1-to-4 solution. Always add the acid to the water. If you do it the other way around, it may cause the solution to spray back, causing serious injury.
-
- If solution does spill over onto the outside of the cell, rinse with water immediately.
- Sulfuric and no fume acid do not give favorable results and are not recommended.
- Allow the solution to sit in the cell for fifteen (15) minutes or until the acid stops bubbling.
- Safely dispose of the solution; pouring it into the pool is recommended.
- Remove the cap from the cell and rinse with light water pressure; re-inspect the cell, and repeat acid cleaning if the cell is still scaled.